PMIS: Print Misclosures
This record specifies options for printing misclosures.
The format of the PMIS record is as follows:
Columns 002-005: PMIS
Columns 007-009: Print misclosures (YES/NO)
Columns 011-013: Print only first pass misclosures (YES/NO)
Columns 015-024: Factor for linear observation types
Columns 026-035: Factor for angular observation types
If the second field is NO, misclosures will not be printed. The two factors control which misclosures are printed: only those misclosures greater in absolute value than the factor times the standard deviation of the corresponding observation are printed (if you want all misclosures printed, set the factors to zero).
Note that this record overrides the corresponding settings in the options file used for the network processing. It is provided for backward compatibility and is not normally used.